HV610-7R5G3 – T峄?膼峄檔g Ho谩 To脿n C岷 //forexgoiler.com T?Động Hoá Toàn Cầu Wed, 04 Jan 2023 02:52:06 +0000 vi hourly 1 //wordpress.org/?v=6.8 //forexgoiler.com/wp-content/uploads/2023/01/cropped-Tu-Dong-Hoa-Toan-Cau-Favicon-32x32.png HV610-7R5G3 – T峄?膼峄檔g Ho谩 To脿n C岷 //forexgoiler.com 32 32 HV610-7R5G3 – T峄?膼峄檔g Ho谩 To脿n C岷 //forexgoiler.com/bien-tan-hnc-hv610-7r5g3/ Sun, 30 May 2021 18:51:20 +0000 //11.duyanhweb.info/san-pham/bien-tan-hnc-hv610-7r5g3/
  • Công suất 7.5kw
  • Điện áp vào 3 pha 380Vac, ra 3 pha 380Vac
  • Ch?đ?điều khiển: V/F, Vector vòng h? Vector vòng kín
  • Truyền thông: RS485, Modbus
  • Bảo hành: 1 năm
  • Ứng dụng: là dòng biến tần đa năng, phù hợp cho hầu hết các bài toán điều khiển động cơ, đặc biệt là các động cơ có mức tải nặng hoặc cần thuật toán điều khiển cao cấp
  • Nguồn bài viết: Biến tần HNC HV610-7R5G3

    ]]>
    tem Specifications
    Basic
    Functionalist
    Highest frequency Vector control: 0 ~ 500 Hz V/F control: 0?200Hz
    Carrier frequency
    0.5kHz?6kHz
    The carrier frequency can be automatically adjusted according to the
    load characteristics.
    Input frequency
    resolution
    Digital setting: 0.01 Hz
    Analog setting: highest frequency * 0.025 %
    Control mode
    1: Open loop vector control
    2: Closed loop vector control
    3: V/F control
    Start torque
    G type: 0.5 Hz / 150 %
    P type: 0.5 Hz / 100 %
    Speed control range 1?00
    Speed stabilization
    accuracy
    ±0.5%
    Torque control accuracy ±5%
    Overload capacity Model G machine: 150 % rated current 60s; 180 % rated current 3s. Torque increase
    Automatic torque increase; The manual torque is increased by 0.1 % – 30.0 %
    V/F curve
    Three ways: linear; Multipoint type; N – power V/F curve
    ( power 1.2, power 1.4, power 1.6, power 1.8, power 2 )
    V/F separation Two methods: full separation and half separation
    Acceleration and
    deceleration curve
    Straight line or S curve acceleration and deceleration mode. Four kinds of acceleration and deceleration times, The acceleration and deceleration time range is 0.0 to 6500.0 S. DC brake
    DC braking frequency: 0.00 Hz ~ maximum frequency
    Braking time: 0.0s ~ 36.0s
    Brake action current value: 0.0 % – 100.0 %
    JOG
    JOG frequency range: 0.00 Hz ~ 50.00 Hz. JOG acceleration and
    deceleration time 0.0s ~ 6500.0 s. Simple PLC, multi-stage
    speed operation
    Up to 16 – speed operation via built-in PLC or control terminal
    Built – in PID
    Closed-loop control system capable of conveniently realize process
    control
    Automatic voltage
    regulation ( AVR )
    When the grid voltage changes, the output voltage can be automatically
    kept constant.
    Mua hàng ?//forexgoiler.com đ?nhận được s?h?tr?k?thuật tốt nhất
    162
    over voltage and
    over-loss rate control
    Automatically limit the current and voltage during operation to prevent
    frequent over current and over voltage trips. Fast current limiting
    function
    Minimize over-current faults and protect the normal operation of the
    frequency inverter
    Torque limitation and
    control
    The ” excavator” feature automatically limits the torque during operation
    to prevent frequent over current trips; Open loop vector mode can
    realize torque control
    Individualized
    performance
    Outstanding
    performance
    Using high performance current vector control technology to realize
    asynchronous motor control
    Stop at once
    When the instantaneous power failure occurs, the load feedback energy
    compensates for the voltage drop and the frequency inverter will continue
    to operate for a short period of time. Fast current limiting Avoiding frequent over current faults of the frequency inverter
    Timing control Timing control function: set the time range from 0.0 min to 6500.0 min
    Switch between two
    motors
    Two sets of motor parameters can realize switching control of two motors
    Bus support Supports a variety of Fieldbus: RS – 485,PROFIBUS
    Running
    Command source
    Operation panel setting, control terminal setting, serial communication
    port setting. Can be switched in various ways
    frequency source
    Multiple frequency sources: digital setting, analog voltage setting, analog
    current setting, pulse setting, serial port setting. Can be switched in
    various ways
    Auxiliary frequency
    source
    Various auxiliary frequency sources. Can flexibly realize auxiliary
    frequency fine tuning and frequency synthesis
    Input terminal
    Standard 7 digital input terminals, of which 1 supports high-speed pulse
    input of up to 100 khz; Three analog input terminals, one supporting
    only 0 ~ 10v voltage input, one supporting 0 ~ 10v voltage input or 4 ~
    20mA current input, 1 analog input terminal, supporting DC ±10V or ±(4~20mA)
    Output terminals
    1 high-speed pulse output terminal ( optional open collector type ), supporting square wave signal output of 0 ~ 100 khz
    1 digital output terminal
    1 relay output terminal
    2 analog output terminals to support 0 ~ 20ma current output or 0 ~
    10v voltage output
    Environment
    Place of use
    Dust – free, metal dust, corrosive gases, flammable gases, oil fog, salt
    fog, water vapor, dripping direct sunlight – free indoor
    Altitude Below 1,000 meters
    Ambient temperature -10℃~40?br /> Humidity Less than 90 % RH without condensation
     Vibration Less than 0.5g. Storage temperature -25℃~65?br /> Protection

    Nguồn bài viết: Biến tần HNC HV610-7R5G3

    ]]>